    SPD single-channel high-voltage polarimeter is developed for colleges and universities to practice piezoelectric ceramic polarization, the equipment is precise and compact, simple and fast operation, applicable to the polarization of thin film and sheet materials, which can make students familiar with and master the polarization method of piezoelectric ceramic materials, cultivate their theoretical practice, analysis and problem-solving ability, and is a necessary experimental instrument for teaching-type piezoelectric ceramic polarization research.

    Polarization mode: corona / air / oil bath polarization
    Temperature control mode: PID precise temperature control
    Operating temperature: 5 ℃ - 40 ℃;
    Number of samples: 1
    Temperature ramp rate: 0-10 ℃ / min
    Storage temperature: -40 ℃ to +65 ℃
    polarization voltage: 0-30KV optional
    Temperature range: RT-200 ℃
    Equipment size: 350 × 325 × 195mm (length, width and height)
    Voltage output accuracy: ±1%
    Sample material: block/film/flake samples
    Equipment power supply: 480W, 220V/60Hz
    Current measurement accuracy: 0.5μA
    Sample size: t≤10mm,φ≤20mm
    Weight: 8kg
    Polarization current: 1mA / each way
    Warranty period: 1 year
    Temperature control accuracy: ±1℃

    enquiry
    • Specifications
    SPD single-channel high-voltage polarimeter is developed for colleges and universities to practice piezoelectric ceramic polarization, the equipment is precise and compact, simple and fast operation, applicable to the polarization of thin film and sheet materials, which can make students familiar with and master the polarization method of piezoelectric ceramic materials, cultivate their theoretical practice, analysis and problem-solving ability, and is a necessary experimental instrument for teaching-type piezoelectric ceramic polarization research.

    Polarization mode: corona / air / oil bath polarization
    Temperature control mode: PID precise temperature control
    Operating temperature: 5 ℃ – 40 ℃;
    Number of samples: 1
    Temperature ramp rate: 0-10 ℃ / min
    Storage temperature: -40 ℃ to +65 ℃
    polarization voltage: 0-30KV optional
    Temperature range: RT-200 ℃
    Equipment size: 350 × 325 × 195mm (length, width and height)
    Voltage output accuracy: ±1%
    Sample material: block/film/flake samples
    Equipment power supply: 480W, 220V/60Hz
    Current measurement accuracy: 0.5μA
    Sample size: t≤10mm,φ≤20mm
    Weight: 8kg
    Polarization current: 1mA / each way
    Warranty period: 1 year
    Temperature control accuracy: ±1℃






     