    The DMS-2000 series high and low temperature dielectric impedance temperature spectrometer is upgraded from the VDMS model, which is unanimously recognized by customers, and the system adopts the principle of parallel plate capacitor and combines with D2149-97 standard design and development. The DMS-2000, together with the self-developed LNP-95 liquid ammonia injection system, can achieve a variable temperature environment from -160°C to 450°C to meet the diversified needs of scientific researches.the self-developed LNP-95 liquid ammonia injection system, can achieve a variable temperature environment from -160°C to 450°C to meet the diversified needs of scientific researches.

    enquiry
    • Specifications

    The DMS-2000 series high and low temperature dielectric impedance temperature spectrometer is upgraded from the VDMS model, which is unanimously recognized by customers, and the system adopts the principle of parallel plate capacitor and combines with D2149-97 standard design and development. The DMS-2000, together with the self-developed LNP-95 liquid ammonia injection system, can achieve a variable temperature environment from -160°C to 450°C to meet the diversified needs of scientific researches.

    Measurement temperature: -160°C~450C
    Ramp rate: 0-10°C/min, typical 3°C/min
    Temperature control accuracy: ±0.5°C
    Measurement frequency: 10μHz~30MHz (depending on the impedance analyzer selected)
    Measurement Accuracy: 0.05%
    Measurement environment: Vacuum atmosphere
    Temperature control method: Multi-stage PID precise temperature control
    Measurement principle: Parallel plate capacitor principle
    Test channels: single channel / five channels, optional
    Test sample: φ<20mm, d< 5mm block
    Electrode material: upper electrode semi-circular type platinum electrode, lower electrode flat type platinum electrode
    Data storage format: TXT text format
    Data transfer: USB communication
    Measurement parameters: Z, Θ, C, D, Z’, Z”, ε’, ε”, tgδ, Cole-Cole
    Power supply: 220V±10%, 50Hz, 2.6kW
    Operating temperature: 5°C to +40C
    Storage temperature: -40C to +65C
    Operating humidity: up to 95% relative humidity at +40%C (non-condensing)
    Equipment size: 520x420x330mm (LxHxW)
    Weight: 35kg
    Warranty: 1 year
    Patent No.: 2015206674968

     

     